How to configure a VertX unit   Before to enroll a VertX unit in Synergis, some preliminary configurations are required Initial configuration The controller is set by default in DCHP to acquire an IP address. To acquire an IP address by DCHP the network port (Ethernet) must be connected before the unit is powered on. To access the web interface of the unit, you may use its IP address or its Virtual Port IP address which is 169.254.242.121. This virtual port is always accessible but can’t be rout
Document Share
Document Tags
Document Transcript
    How to configure a VertX unit Before to enroll a VertX unit in Synergis, some preliminary configurations are requiredInitial configuration   The controller is set by default in DCHP to acquire an IP address. To acquire an IP addressby DCHP the network port (Ethernet) must be connected before the unit is powered on.To access the web interface of the unit, you may use its IP address or its Virtual Port IPaddress which is 169.254.242.121. This virtual port is always accessible but can’t be routedon a network and is common to all VertX controller.The default user/password is Admin with no password or you may also use the account toenroll the controller which is root/passBasic setup page   ã   Set the IP address of the controller, if the unit and the server are on different VLAN,set a static IP address for the unit. ã   Set a password for the Admin user ã   SaveAdvanced Network Setup   This page gives access to the same option as the Basic setup page with the possibility to seta hostname for the unit. The hostname should be 1- 16 alphanumeric characters long, nospace and no special characterSystem Status   This page display any inputs in alarm, it also let you test an input/ouput, add an unconfiguredmodule and verify the firmware version ã To access the icon legend, click on the link on the top right corner ã Any icon displayed in Red, means that either an input is misconfigured or there is aproblem with that input. ã Click on 'Add unconfigured' to add any modules (V100, V200, V300) not displayed onthis page (for the modules to be recognized in Synergis, the V1000 need to berestarted) ã The version should be 2.2.7.18 ã The Program/EEprom versions for a V100 should be 113 & 110    ã The Program/EEprom versions for a V200 should be 106 & 105   ã The Program/EEprom versions for a V300 should be 107 & 104Supplemental configuration   Prior to version 1.2, this had to be set before enrolling the unit in Synergis, now it can bedone in the Config ToolClick on the Module you want to configure (V2000 or V100 icon)Wait until you see a dot next to the door behavior before editing anything.1. Select the appropriate door behavior for this interface2. In the door monitor section, make sure the minimum open time is greater than '0'3. If you need to change the default state of an input, swap the HRUL with the LRULvalues and do the same with the HRLL and LRLL values.4. To configure supervised input, please refer to the following table :Reader interface V100 or Output control interface V300N/C switch (Door Switch) N/O switch (REX Switch)4 états 2 états 4 états 2 états2K/1K 4K/2K 2K/1K 4K/2KHRUL 180 196 196HRUL215215 255HRLL 159 159 0HRLL 181197 197LRUL 215 215 255LRUL 180196 196LRLL 181 197 197LRLL 159159 0Input monitor interface V200N/C switch N/O switch4 états 2 états 4 états 2 états2K/1K 4K/2K 2K/1K 4K/2KHRUL 89 131 128HRUL133175 255HRLL 80 118 0HRLL 120158 129LRUL 133 172 255LRUL 89132 128LRLL 120 155 129LRLL 80119 0    Sometimes although the firmware installed is the right version, Synergis fails to enroll thecontroller trying to retrieve the eeprom settings.If this happens in the supplemental configuration page click on this iconThis will open the update system page and let you select the modules you want to update.The modules program code are held in the controller firmware but sometimes needs to berefreshed. The process takes about 2-3 minutes. Support DID: (514) 856-7100 Support Toll Free (Canada & US): 1-866-338-2988 Email:   support@genetec.com   Web:   http://www.genetec.com/english/customercare/support/overview.aspx  
We Need Your Support
Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

Thanks to everyone for your continued support.

No, Thanks
SAVE OUR EARTH

We need your sign to support Project to invent "SMART AND CONTROLLABLE REFLECTIVE BALLOONS" to cover the Sun and Save Our Earth.

More details...

Sign Now!

We are very appreciated for your Prompt Action!

x