Pressure Transducer

of 17
8 views
PDF
All materials on our website are shared by users. If you have any questions about copyright issues, please report us to resolve them. We are always happy to assist you.
Document Description
Pressure Transducer Pressure Transducer c Pressure - Electronic Pressure Switches - Mechanical Pressure Switches - Pressure Transducer c Valves & Regulators c Temperature c Level c Flow c Air Suspension Valves Table of Contents Pressure Transducer Series 423X, 425X, 426X - Explosion Proof Transducer (Amplified) Series 443, 445, 446 - Intrinsically Safe Transducer Series 433, 435, 436 - Non-Incendive Transducer Series 423N1, 425N1, 426N1 - General Industrial J-Box Series 423, 425, 426 - Gener
Document Share
Document Tags
Document Transcript
  c   Pressure- Electronic Pressure Switches- Mechanical Pressure Switches-Pressure Transducer c    Valves & Regulators c   Temperature c   Level c   Flow c    Air Suspension Valves Pressure Transducer Pressure Transducer  Pressure Transducer   Series 423X, 425X, 426X - Explosion Proof Transducer (Amplified) 3 Series 443, 445, 446 - Intrinsically Safe Transducer 5 Series 433, 435, 436 - Non-Incendive Transducer 7 Series 423N1, 425N1, 426N1 - General Industrial J-Box 9 Series 423, 425, 426 - General Industrial Transducer (Amplified) 11 Series 420, 422 - General Industrial Transducer (Unamplified) 13 Series 623, 625, 626, 627 - OEM Transducer 15 Table of Contents  Transducer   Explosion Proof Transducer (Amplified) Series 423X, 425X, 426X  Features Diffused silicon sensor for high accuracyExplosion proof enclosure for hazardous locationsSuperior EMI, ESD and RFI protectionRugged stainless steel constructionNEMA 4X, 7 and 9    ATEX approved for 425X Series onlyModular concept   Built-in high pressure snubber (2000 psi and above)   cULus, CE approved  Applications  Oil & gas pipelines Oil patch Petrochemical plants Refineries Pulp and paper mills General Specifications* * See product configurator for additional options. 1 4 2 5  X   AT E  X  AP P R O V E D   Coal and oil fired power plants   Cement plants   Gas transfers for fuel systems   Gas panels   Gas mixing systems  Accuracy (LH & R): ±0.25% BSL (±0.5% for vacuum only [-23]) Long Term Stability: ±0.5% FSO of calibration curve Typical Life Cycle: 100 million cycles Proof Pressure: 2 times rated pressure or 13,000 psi max.(884 bar), whichever is less Input: 423X:426X:425X:Excitation voltage: 9 to 28 VDCExcitation voltage: 14 to 28 VDCExcitation voltage: 12 to 28 VDC Supply Current: 3.0 mA maximum (no load) Output: 423X:426X:425X:Output: 0.5 to 5.5 VDCFull scale output: 5.0 VDC ± 0.8%Zero output: 0.5 VDC ± 0.4%Output: 1 to 11 VDCFull scale output: 10 VDC ± 1%Zero output: 1.0 VDC ± 2%Output: 4 to 20 mAFull scale output: 16 mA ± 1%Zero output: 4 mA ± 2% Wetted Parts: 17-4 PH & 300 series stainless steel Enclosure: NEMA 4, 300 series stainless steel Pressure Connection: 1/4”-18 NPT male ElectricalConnection: 3 conductor for voltage series and 2 conductorfor current series, 24 awg, PVC jacketed,shielded cable, 3 ft. (1 m) long with integralstrain relief and case ground (standard). Temperature Ranges: Operating:Compensated:Storage:-40° to 185°F (-40° to 85)°C30° to 160°F (-1° to 71)°C-40° to 185°F (-40° to 85)°C Temperature Shift: Zero & Span:0.0125% per °F over compensated range 75°Freference  Vibration: 15 g’s, 10-2000 Hz, MIL-STD 202 Shock: 50 g’s, 11 mS, MIL-STD 202 Method 213,Cond. G.  Approvals: UL cUL approved as telemetering equipmentfor use in hazardous locations (UL File E146589,WYMV, WYMV7) as follows:Class I, Div. 1, Groups A, B, C & DClass II, Groups E, F & G, when installed inaccordance with control drawing 272148.1/2” NPT male conduit models and 1/2” NPTFconduit/DIN connector models are also ULlisted as nonincendive devices, approved foruse in Class I, Div. 2, Groups A, B, C, D, ClassII, Groups F & G, hazardous locations (withoutbarriers). Weight: 423X & 426X:425X:7.4 oz. (221 grams) to 1000 psi9.9 oz. (281 grams) 2,000 psi and higher7.4 oz. (210 grams) to 1000 psi9.4 oz. (266 grams) 2,000 psi and higher Warranty: 1 year warranty MILLIVOLT SERIES - 423X & 426X(T4/T5)(H3/H5)Signal 1Red+ Excitation3White+ Output2BlackCommon4BareDrain MILLIAMP SERIES - 425X 1Red+ Excitation4Black- Excitation3BareDrain Wiring Code  Explosion Proof Transducer (Amplified) Series 423X, 425X, 426X  Technical DrawingsProduct Configurator Example:   425X-04-A See Barksdale’s Standard Conditions of Sale ã Specifications are subject to modification at any time ã Bulletin #R0031-E ã 02/11 ã ©2011 ã Printed in the U.S.A.2 3211 Fruitland Avenue ã Los Angeles, CA 90058 ã  800-835-1060 ã Fax: 323-589-3463 ã www.barksdale.com Base Model 423X 0.5 - 5.5 VDC analog ouput425X 4 - 20 mA analog output426X 1 - 11 VDC analog output Pressure Range -23 0 - 29.9” of Hg-01 0 - 15 psi (0 - 1 bar) 2 -21 0 - 30 psi (0 - 2.1 bar) 2 -22 0 - 60 psi (0 - 4.1 bar) 2 -03 0 - 50 psi (0 - 3.5 bar) 2 -04 0 - 100 psi (0 - 6.9 bar) 2 -05 0 - 150 psi (0 - 10.3 bar) 2 -06 0 - 200 psi (0 - 12.8 bar) 2 -07 0 - 300 psi (0 - 20.7 bar) 2 -08 0 - 500 psi (0 - 34.5 bar)-19 0 - 600 psi (0 -41 bar)-10 0 - 1,000 psi (0 - 69 bar)-12 0 - 2,000 psi (0 - 138 bar)-13 0 - 3,000 psi (0 - 207 bar)-14 0 - 4,000 psi (0 - 276 bar)-15 0 - 5,000 psi (0 - 345 bar)-16 0 - 6,000 psi (0 - 414 bar)-17 0 - 7,500 psi (0 - 517 bar)-18 0 - 10,000 psi (0 - 689 bar) Blank  Gauge pressure (standard)-A Absolute pressure range (<300psi) Blank  1/4-18 NPT male (standard)-P1 7/16-20 UNF-2B female-P3 7/16-20 UNF-2B male Process Connection -Z101 to 5V output (available only on423X models)-Z111 to 6V output (available only on423X models)-Z120.5 to 4.5V output (available onlyon 423X models)-Z162 to 10V output (available onlyon 426X models)-Z15Calibrated in bars-Z17 3 For high pressure models withlarger orifice-Z18Z17 and Z10 options combined-ZXXYSpecial pressure ranges(see note 1)-WXXX Additional length of free leads(in inches) Options Note 1: Add suffix ZXXY for special pressure range calibration. XX = significant digits. Y = number of trailing zeros. Example: 130 psi calibration: add -Z1312: Available in absolute range3: For pressure >10kpsi with a 3/16 diameter pressure port orifice, no surge protector will be offered.4: Minimum quantities may apply. 423X/426X425X
We Need Your Support
Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

Thanks to everyone for your continued support.

No, Thanks
SAVE OUR EARTH

We need your sign to support Project to invent "SMART AND CONTROLLABLE REFLECTIVE BALLOONS" to cover the Sun and Save Our Earth.

More details...

Sign Now!

We are very appreciated for your Prompt Action!

x