System Specification i2000 - i2000sr - c8x00 - c16x00

of 19
10 views
PDF
All materials on our website are shared by users. If you have any questions about copyright issues, please report us to resolve them. We are always happy to assist you.
Document Description
System Specifications i2000 i2000SR c8x00 c16x00 The following system specifications are included in this section: ã ã ã ã ã ã ã ã ã Site Requirements for Operations Manual Use Approximate Physical Measurements Clearance Measurements for Operation and Service Electrical, Power, and Heat Output Specifications Water and Waste Specifications Seismic Anchoring Specifications Environmental Specifications Floor Loading Specifications Dimensional Layout Drawings Operations Manual Use Use Minimum Syst
Document Share
Document Tags
Document Transcript
  System Specifications i2000 i2000SR c8x00 c16x00   The following system specifications are included in this section:   ã Site Requirements for Operations Manual Use   ã Approximate Physical Measurements   ã Clearance Measurements for Operation and Service   ã Electrical, Power, and Heat Output Specifications   ã Water and Waste Specifications   ã Seismic Anchoring Specifications   ã Environmental Specifications   ã Floor Loading Specifications   ã Dimensional Layout Drawings    Operations Manual Use   Use Minimum System Requirements A computer workstationshould be available in the labfor installation and use of theARCHITECT SystemOperations Manual CD-ROM.   Additionalcomputerworkstation fordisplay of theoperations manual   This workstation is in additionto the SCC.   If an additional workstation isnot available, a printedoperations manual can beordered.   ã Windows® 95 or Windows 2000Operating System   ã Pentium® II Processor   ã 640 Mb RAM   ã 24x CD-ROM Drive   ã 17 Color Monitor (800x600resolution)   Caution  It is highly recommended that the customer perform a system backup prior to installation of the operations manual. Note  This installation program installs Internet Explorer 5.0 over the current version of Internet Explorer. To ensure proper viewing, set the resolution of the monitor to 800x600.  Approximate Physical Measurements   System / Module Depth Width Height Weight c16000 (with Retest Sample Handler notincluding SCC, or Waste Option)   49 (124.5cm)   79 (200.6cm)   48 (121.9cm)   1545 lbs.(701 kg)   c8000 (with Retest Sample Handler notincluding SCC, or Waste Option)   49 (124.5cm)   79 (200.6cm)   48 (121.9cm)   1425 lbs.(646.4 kg)   i2000SR (with Retest Sample Handler, notincluding SCC, ARCHITECT ARM, or WasteOption)   49 (124.5cm)   61 (154.9cm)   48 (121.9cm)   1081 lbs.(490.3 kg)   ci16200 Integrated System (with RetestSample Handler, not including SCC,ARCHITECT ARM, or Waste Option)   49 (124.5cm)   127 (322.6cm)   48 (121.9cm)   2679 lbs.(1215 kg)   ci8200 Integrated System (with Retest SampleHandler, not including SCC, ARCHITECTARM, or Waste Option)   49 (124.5cm)   127 (322.6cm)   48 (121.9cm)   2447 lbs.(1109.9 kg)SCC   21 (53.3cm)   15.5 (39.4cm)   22 (55.9cm)   55 lbs. (25kg)   Uninterruptible Power Supply (UPS) (Optional- for the SCC)   17.8 (45.2cm)   6.9 (17.5cm)   9.1 (23.1 cm)   43 lbs.(19.5 kg)   Waste Pump   13 (33.0cm)   13 (33.0cm)   13 (33.0cm)   18 lbs. (8.2kg)   ARCHITECT ARM (Automatic ReconstitutionUnit)   17.8 (45.2cm)   22.9 (58.2cm)   28.3 (71.9 cm)   69 lbs.(31.3 kg)    Clearance Measurements for Operation and Service   Device Location Clearance   Description Note  See Dimensional Layout Drawings . Sides (AllModules)   24 (61.0cm)   Left and right clearance (for access)   Rear(c8000/i2000SR    /c16000)   30 (76.2cm)   Single Module System clearancebetween rear module covers and wall(for safety access to main circuitbreakers, cooling, airflow, cable andtubing routing, and maintenance)   Rear(ci8200/ci16000)   30 (76.2cm)   Multi-Module System clearancebetween the rear module covers andwall (for safety access to main circuitbreakers, traffic, and maintenance)   Above (AllModules)   20 (50.8cm)   Clearance above modules (to open topcover)   Processing Module(c8000, i2000SR,ci8200, c16000,ci16200 IntegratedSystem)   Front (AllModules)   34 (86.4cm)   Clearance in front of modules (forsafety and to allow access for removaland replacement of bulk liquids/waste)   Door and EntryRequirements(c8000)   Doorways AndEntryways   31 (78.7cm)   The c8000 module requires 31 (78.7cm) wide openings for doorways andentryways between the delivery areaand the laboratory. Verify door widthfor each door from dock to lab is 31 (78.7 cm) or wider.   Note  For doors less than 31 (78.7 cm), removal of door and hinges may be required. For door openings less than 31  (78.7 cm) wide, an alternate method of getting the module to the lab needs to be found. Door and EntryRequirements(c16000)   Doorways AndEntryways   34.5 (87.6cm)   The c16000 module requires 34.5 (87.6 cm) wide openings for doorwaysand entryways between the deliveryarea and the laboratory. Verify doorwidth for each door from dock to lab is34.5 (87.6 cm) or wider.   Note  For doors less than 34.5  (87.6 cm), removal of door and hinges may be required. For door openings less than 34.5  (87.6 cm) wide, an alternate method of getting the module to the lab needs to be found. Door and Entry Doorways And 36 (91.4 The i2000SR module requires 36
We Need Your Support
Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

Thanks to everyone for your continued support.

No, Thanks
SAVE OUR EARTH

We need your sign to support Project to invent "SMART AND CONTROLLABLE REFLECTIVE BALLOONS" to cover the Sun and Save Our Earth.

More details...

Sign Now!

We are very appreciated for your Prompt Action!

x